- Quality of the measurement data is medium.
- Origin of the data is K ARRAY.
- Format of the data is a GLL file .
-
Sensitivity:
- Measured: 103.9 dB (avg. 300Hz-3kHz for 2.83V estimated at 1m).
- Measured: 83.9 dB computed at the measurement distance (10.0m) over the same frequency range.
- -3dB (resp. -6db) point v.s. reference is at 109.0Hz (resp. 106.0Hz).
- Reference level is normalised to -0.2dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 4.7dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is -4.71
and would be -0.83 with a
perfect subwoofer.
- Details: NBD: ON 1.664, LW 1.462, SP 1.515, PIR 1.467; SM: SP0.031, PIR0.006; LFQ 4.813, LFX 115Hz
- Tonality (Preference) Score is -3.26
with an EQ and would be 0.66 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 1.471, LW 1.261, SP 1.371, PIR 1.298; SM: SP0.024, PIR0.225; LFQ 4.813, LFX 118Hz
- Tonality (Preference) Score is -4.71
and would be -0.83 with a
perfect subwoofer.